Annis Enclosed Demagnetizers


These enclosed type Demagnetizers have ribbed, cast aluminum housings for better convection cooling. They are available in the following sizes and ratings. All listed units are rated for dry operation on 60 Hz, single phase. Intermittent rated units up to 21KVA are rated 25% duty, with a maximum ON time of five minutes. Intermittent 42 KVA units are rated at 15% duty with a maximum ON time of three minutes. For 50 Hz operation, add 10% for same size and rating. Units with XX Listing have a higher demagnetizing field strength.

R

Size

Duty

Volts

Amps

KVA

Field

Wt

Connection

1 3 ½" X Int.

120

4.3 .52

440

13

cord & switch

2 3 ½" X Cont.

120

1.27 .16

242

15

cord & switch

3 3 ½" X Int.

240

2.75 .66

480

15

cord & switch

4 3 ½" X Cont.

240

.87 .21

265

16

cord & switch

5 3 ½" X Int.

480

1.74 .84

530

16

cord only

  3 ½" XX14 Int.

120

6.5 .78

540

14  
  3 ½" XX16 Cont.

120

2.16 .26

295

15  
  3 ½" XX16 Int.

240

4.3 1.04

590

15  
  4 ½" X Cont.

120

13.3 1.6

500

53  
  4 ½" XX6 Int.

240

40.0 9.6

1200

65  
  4 ½" XX6 Cont.

120

20.0 2.4

600

65  
  4 ½" XX6 Int.

120

54.0 6.5

1400

70  
  4 ½" XX9 Int.

480

19.8 9.5

1200

64  
  4 ½" XX12 Cont.

480

5.0 2.4

600

63  
1 6" N Int.

120

11.2 1.34

360

24

cord & switch

2 6" N Cont.

120

4.3 .51

212

32

cord & switch

3 6" N Int.

240

8.5 2.04

420

34

cord & switch

4 6" N Cont.

240

2.16 .51

215

31

cord & switch

5 6" N Int.

480

4.3 2.06

480

31

cord only

1 6" X Int.

120

21.6 2.6

510

35

cord only

2 6" X Cont.

120

5.4 .65

250

34

cord & switch

3 6" X Int.

240

10.8 2.6

500

34

cord only

4 6" X Cont.

240

3.5 .84

280

37

cord & switch

5 6" X Int.

480

7.0 3.36

560

37

cord only

  6" XX9 Cont.

120

10.8 1.3

350

45  
  6" XX9 Int.

240

21.6 5.2

700

45  
  6" XX12 Cont.

240

5.4 1.3

345

45  
  6" XX12 Int.

480

10.8 5.18

700

45  
  6" XX16 Cont.

480

2.1 1.01

308

42  

R

Size

Duty

Volts

Amps

KVA

Field

Wt

Connection

1 10" N Cont.

120

21.6 2.62

230

74

6’ leads

2 10" N Int.

240

43.7 10.5

460

74

6’ leads

3 10" N Cont.

240

10.8 2.6

240

73

6’ leads

4 10" N Int.

480

21.6 10.5

480

73

6’ leads

5 10" N Cont.

480

5.4 2.6

236

71

6’ leads

1 10" X Int.

240

87.5 21.0

695

106

6’ leads

2 10" X Cont.

240

21.6 5.2

335

105

6’ leads

3 10" X Int.

480

43.2 21.0

680

105

6’ leads

4 10" X Cont.

480

10.8 5.2

340

109

6’ leads

1 2" x 5" N Int.

120

8.3 1.0

500

20

cord & switch

2 2" x 5" N Cont.

120

2.25 .27

250

19

cord & switch

3 2" x 5" N Int.

240

4.5 1.08

500

19

cord & switch

  2" x 5" N Cont.

240

1.42 .34

260

22  
1 2" x 5" X Int.

120

21.6 2.6

720

28

cord & switch

2 2" x 5" X Cont.

120

3.4 .41

320

22

cord & switch

3 2" x 5" X Int.

240

10.8 2.6

790

26

cord & switch

  2" x 5" XX11 Cont.

120

6.6 .79

425

30  
  2" x 5" XX11 Int.

240

13.2 3.1

850

30  
  2" X 5" X Cont.

240

2.7 .66

380

30  
  2" x 5" XX18 Cont.

480

1.4 .67

390

28  
1 4" x 7" N Int.

120

21.6 2.6

460

37

cord or box

2 4" x 7" N Cont.

120

10.8 1.3

300

47

cord or box

3 4" x 7" N Int.

240

21.6 5.2

600

47

cord or box

4 4" x 7" N Cont.

240

5.4 1.3

300

47

cord or box

5 4" x 7" N Int.

480

10.8 5.2

600

47

cord or box

1 4" x 7" X Cont.

120

21.6 2.6

430

72

cord or box

2 4" x 7" X Int.

240

43.7 10.5

860

72

leads or box

3 4" x 7" X Cont.

240

10.8 2.6

430

70

cord or box

4 4" x 7" X Int.

480

21.6 10.5

860

70

cord or box

5 4" x 7" X Cont.

480

5.4 2.6

430

73

cord or box


 

R

Size

Duty

Volts

Amps

KVA

Field

Wt

Connection

  4" x 9 ½" N Int.

120

21.6 2.6

354

41  
  4" x 9 ½" N Cont.

129

10.8 1.3

240

49  
  4" x 9 ½" N Int.

240

21.6 5.2

480

49  
  4" x 9 ½" N Cont.

240

5.4 1.3

240

51  
  4" x 9 ½" N Int.

480

10.8 5.2

480

51  
  4" x 9 ½" N Cont.

480

2.7 1.3

240

51  
  4" x 9 ½" X Cont.

120

21.6 2.6

350

78  
  4" x 9 ½" X Int.

240

43.7 10.5

700

78  
  4" x 9 ½" X Cont.

240

10.8 2.6

350

75  
  4" x 9 ½" X Int.

480

21.6 10.5

700

75  
  4" x 9 ½" X Cont.

480

5.4 2.6

350

82  
1 4 ½" x 14" Int.

120

21.6 2.6

300

46

cord only

2 4 ½" x 14" Cont.

120

10.8 1.3

210

58

cord & switch

3 4 ½" x 14" Int.

240

21.6 5.2

420

58

cord only

4 4 ½" x 14" Cont.

240

5.4 1.3

410

57

cord & switch

5 4 ½" x 14" Int.

480

10.8 5.2

420

57

cord only

6 4 ½" x 14" Cont.

480

2.7 1.3

210

57  
1 6" x 14" Cont.

120

21.6 2.6

240

97

6’ leads

2 6" x 14" Int.

240

87.5 21.0

650

121

6’ leads

3 6" x 14" Cont.

240

21.6 5.2

325

122

6’ leads

4 6" x 14" Int.

480

43.7 21.0

650

122

6’ leads

5 6" x 14" Cont.

480

10.8 5.2

325

120

6’ leads

1 8" x 24" Int.

240

87.5 21.0

410

154

6’ leads

2 8" x 24" Cont.

240

43.7 10.5

275

198

6’ leads

3 8" x 24" Int.

480

87.5 42.0

550

198

6’ leads

4 8" x 24" Cont.

480

21.8 10.5

275

197

6’ leads

  8" x 24" Int.

480

43.7 21.0

410

155  
  14" x 16" Cont.

120

43.7 5.25

165

154  
  14" x 16" Int.

240

87.5 21.0

330

154  
  14" x 16" Int.

240

175.0 42.0

450

192  
  14" x 16" Cont.

240

43.7 10.5

225

192  
  14" x 16" Int.

480

87.5 42.0

450

192  
  14" x 16" Cont.

480

21.8 10.5

225

192  
  14" x 16" Int.

480

43.7 21.0

330

154  

 Features

Sturdy Ribbed Case Design on these totally enclosed units gives increased mechanical protection and extra heat radiating surface. This allows maximum power input to produce stronger demagnetizing fields.

Demagnetizer Installation should allow adequate circulation of cooling air around the Unit. It should not be too close to large steel or metal structures due to possible heating from induced "eddy" currents. The recommended minimum distance is equal to the mean demagnetizer coil diameter.

Demagnetizers Connect Directly to 60 cycle, single phase, AC power lines - no transformer required.

Dry Type Units are designed for indoor use and should be protected from water and oil, drip or spray.

Water Proof Units are furnished with connecting cords or leads only, no self-contained switch or pilot light.

Options

Red Pilot Light available when ordered with enclosed, dry-type demagnetizers.
Mutiple Station AC Demagnetizers for fast moving work, etc.
50 Cycle Operation add 10% to 60 cycle prices.

Export Packing Plus 4%,  Replacement Toggle Switch

Prices are subject to change without notice.


Return To Top

Home

Back

Sales

maganim.gif (57170 bytes)

Request Information

Site Map

Magnetic Instrumentation, Inc.
8431 Castlewood Dr.
Indianapolis, IN 46250-1534


E-mail: maginst@maginst.com
Tel. 317-842-7500
Fax 317-849-7600