![]() Magnetizer/Demagnetizer
|
Description
The Model 9500 is a high voltage (2000 VDC), medium
energy (4.8 kJ) combination magnetizer and RINGING demagnetizer designed for
processing large volumes of Barium Ferrite and NEO (NdFeB) materials. Wire wound fixtures
are used in conjunction with the Model 9500 for magnetizing and demagnetizing a wide range
of magnets and certain types of permanent magnet motors, loud speakers, accelerometers,
TWT stacks, large holding magnets and many magnet assemblies. It is microprocessor
controlled and is supplied in a roll around Euro-style enclosure. The unit is equipped
with many safety features including safety drain circuit, electrical door interlocks,
grounding wand, thermal protectors, and emergency stop. The selection of a
magnetizing/demagnetizing system begins with an analysis of the production requirements,
including magnet material, magnet size, magnetizing orientation, magnet load line or
operating point, number of poles, production speed, magnet measuring and other operations
that may be necessary. Once these factors are understood and samples and/or drawings are
made, our applications engineers can recommend a system to meet your requirements.
|
|
Demag Fixtures:
Fixtures can be designed for demagnetizing NEO with inside diameters up to 3.5"
with a 2" active length. Fixtures can be designed for demagnetizing Ferrite with
inside diameters up to 5.5" with a 3" active length.
Available Options: |
|
Specifications
Energy & Capacitor Level:
Model 9500 4.8 kJ at 2000 VDC
2400 uF Capacitance
Peak Magnetizing Fields Using Wire-Wound
Fixtures:
1" I.D. Minimum 50,000 Oersteds
3.5" I.D. Minimum 20,000 Oersteds
5.5" I.D. Minimum 15,000 Oersteds
Input Power Requirements: (Please specify preference at time of order)
220/240 VAC 30 Amps 50/60 Hz
440/480 VAC 15 Amps 50/60 Hz
Weight: (Net) Model 9500 (Max.) 450 lb (204 kg)
Dimensions:
Height: 42 in (106.7 cm)
Width: 22 in ( 55.9 cm)
Depth: 31 in ( 78.7 cm)
Selectable Wave Forms: The rise time to the peak and overall pulse length will depend on the fixture impedance and the capacitance of the magnetizer.
Magnetize: Sinusoidal or Exponential Pulse

Demagnetize: Ringing/Decaying AC

Specifications subject to change without notice.
Contact our factory for additional
information.
Magnetic Instrumentation, Inc., 8431 Castlewood Dr., Indianapolis, IN 46250-1534,
E-mail: maginst@maginst.com, Tel. 317-842-7500,
Fax 317-849-7600