Description
The Model 990 Series Magnetreaters® are highly accurate, pulse type, ringing
demagnetizers (also called treaters) for the controlled stabilization of permanent magnets
and permanent magnet assemblies. Regardless of line voltage stability they provide a
controlled output through continuous pulse amplitude regulation. Treating voltage is
variable from 0 to 600 VDC. Additional energy can be added to the Model 990 Series by
interconnecting a Model 992 Energy Booster. The energy level is increased from 18 to 36
watt-seconds. With this option treating coils will produce higher demagnetizing fields and
lower ringing frequencies, which can provide greater field penetration in some
applications.
Model 990A
The Model 990A Magnetreater® is designed for manual control of treating or it
can be equipped with the optional IEEE-488 interface module and D/A reference generator
module for computer control. The unit has two output controls for manually adjusting the
treating pulse output, a pulse rate control, and a series of front panel lights to
indicate system status.
IEEE-488 Interface
This option allows the Magnetreater to be controlled by an external computer. A
Gaussmeter with a parallel BCD output is connected to the "Talk" port in the
Magnetreater®. A 24 pin IEEE-488 connector is located on the rear panel of the 990, along
with the BUS address switch.
Model 990C
The 990C Magnetreater® has all the functions of the Model 990A, with the
addition of the dual slope and automatic control circuitry. The dual slope control enables
the output to be gradually increased at one or two different rates from an initial
starting level. Front panel controls adjust the rate of increase for both the fast and
slow slopes. A reset control allows the operator to return the output to the initial
starting level upon completion of a treat cycle. The automatic control utilizes the analog
output from the Model 912 Gaussmeter or 912T Teslameter to provide a closed loop,
automatic treating system. A digital front panel meter is used to adjust the desired treat
level as a percentage of full scale and to display the magnetic field level of the magnet
being processed.
Specifications
| Model
990A & 990C Energy
Storage: |
Dimensions: Weight: 42 lb (19.0 kg) Width: 19.0 in (48.3 cm) Height: 7.0 in (17.8 cm) Depth: 15.5 in (39.4 cm)